TCL Error Code

Failure type = In and out communication failure

LED CODE = RUN,TIMER -both winking

DIGITAL LED CODE = E0 


Failure type = Outdoor communication failure

LED CODE = RUN,TIMER -both winking

DIGITAL LED CODE = EC 


Failure type = Outdoor sensor

LED CODE = RUN-1 time/8s

DIGITAL LED CODE = E1 
Failure type = Indoor coil temperature sensor

LED CODE = RUN-2 times/8s

DIGITAL LED CODE = E2 
Failure type = Outdoor coil temperature sensor

LED CODE = RUN-3 times/8s

DIGITAL LED CODE = E3

Failure type = System abnormity

LED CODE = RUN-4 times /8s


DIGITAL LED CODE = E4 

Failure type = Type mismatch

LED CODE = RUN-5 times /8s

DIGITAL LED CODE = E5 

Failure type = Indoor fan motor

LED CODE = RUN-6 times /8s

DIGITAL LED CODE = E6 

Failure type = Outdoor temperature sensor

LED CODE = RUN-7 times /8s

DIGITAL LED CODE = E7 

Failure type = Discharge temperature sensor

LED CODE = RUN-8 times /8s

DIGITAL LED CODE = E8 

Failure type = Invert module abnormity

LED CODE = RUN-9 times /8s

DIGITAL LED CODE = E9 

Failure type = Outdoor fan motor (DC) 

LED CODE = RUN-10 times /8s

DIGITAL LED CODE = EF 

Failure type = Current sensor

LED CODE = RUN--11 times /8s

DIGITAL LED CODE = EA 

Failure type = EEPROM failure

LED CODE = RUN-12 times /8s

DIGITAL LED CODE = EE 

Failure type = Top of compressor temperature switch

LED CODE = RUN-13 times /8s

DIGITAL LED CODE = EP 

Failure type = Voltage sensor

LED CODE = RUN-14 times /8s

DIGITAL LED CODE = EU 

Protection display code list:














Protection type = higher or lower voltage

LED CODE = RUN-winking,TIMER-1 time/8s 

DIGITAL LED CODE = P1 

Protection type = Over current

LED CODE = RUN- winking,TIMER-2 times /8s

DIGITAL LED CODE = P2 

Protection type = Discharge temperature

LED CODE = RUN- winking,TIMER-4 times /8s

DIGITAL LED CODE = P4 

Protection type = Over cooling in cooling mode

LED CODE = RUN-light,TIMER-5 times /8s

DIGITAL LED CODE = P5 

Protection type = Over heating in cooling mode

LED CODE = RUN- light,TIMER-6 times /8s

DIGITAL LED CODE = P6 

Protection type = Over heating in heating mode

LED CODE = RUN- light,TIMER-7 times /8s

DIGITAL LED CODE = P7 

Protection type = Outdoor temperature too high or low 
LED CODE = RUN- light,TIMER-8 times /8s

DIGITAL LED CODE = P8
 
Protection type = Drive protection(Overload)

LED CODE = RUN- winking,TIMER-9 times/8s

DIGITAL LED CODE = P9 

Protection type = Module self protection

LED CODE = RUN- winking,TIMER-10 times/8s

DIGITAL LED CODE = P0 

Outdoor failure display
There is a LED on outdoor power board, when compressor is running; it is normally light;
when no feedback of signal to power board from compressor, it will wink by lighting 1s and
going out 1s. If failures happened, it will light 0.5s, go out 0.5s, winking several times and go
out 3s for a cycle to indicate failures. The failure list is the follow: 


Wink time = 1

Failure = IPM protection 
Wink time = 2

Failure = higher or lower voltage

Wink time = 3

Failure = Over current 

Wink time = 4

Failure = Discharge temperature too high 

Wink time = 5

Failure = Outdoor coil temperature too high 

Wink time = 6

Failure = Drive abnormity 

Wink time = 7

Failure = Communication abnormity with indoor unit 

Wink time = 8

Failure = Compressor over heat (switch on top of compressor) 
Wink time = 9

Failure = Outdoor air temperature sensor failure
 
Wink time = 10

Failure = Outdoor coil temperature sensor failure 

Wink time = 11

Failure = Outdoor discharge pipe temperature sensor failure 